× 1-800-946-2642 Home My Account Social / Forum Articles Contact My Cart
Shop Now
Select Your Car Type Sale Items Clearance Items New Items
   Forum Width:     Forum Type: 

 Posted: Nov 15, 2021 08:50AM
Total posts: 499
Last post: Apr 14, 2024
Member since:Jan 25, 2017
Cars in Garage: 0
Photos: 0
WorkBench Posts: 0
I've been using the plastic covered spades. I think that is part of the problem, you really can't see the actual crimp. OneTim, That is a great solution of positive connection.

 Posted: Nov 15, 2021 06:21AM
Total posts: 1007
Last post: Jul 19, 2022
Member since:Jul 24, 2014
Cars in Garage: 0
Photos: 0
WorkBench Posts: 0
Beyond tinning, I like to solder wire connections after crimping, then shrink wrap.

 Posted: Nov 14, 2021 04:11AM
 Edited:  Nov 14, 2021 04:16AM
Total posts: 8592
Last post: Apr 6, 2024
Member since:Sep 30, 2002
Cars in Garage: 4
Photos: 40
WorkBench Posts: 2
CA
I once got a smokin' deal on a (used) small Kubota diesel tractor/mower.  The mechanics (@ the dealer) I asked about it told me not to buy it.  They could not say too much (legally I guess?)...just a lot of head shakin', mumbling and 'don't do it man'''' stuff.
The salesman charged me likely 1/3 or 1/4 of the going rate and gave me double what my trade in POS mower was worth.

I mowed with it once or twice (I forget exactly) then one time I got called away mid-mow and came back later on and the dang thing wouldn't start.  Dead !  Didn't like leaving it out on the front lawn all night, but there it sat.
Aha! I said.  This is why I got such a smokin' deal.

Long story short, it ended up being the crimp inside the "signal wire" spade connector on top of the starter solenoid.  With a cup of coffee next morning and a little troubleshooting, after I figured it out, Ten minutes later, I was mowing.  That was about 15yrs and 500 mower hours ago.

  ~ 30 minutes in a Mini is more therapeutic than 3 sessions @ the shrink. ~

  Mike  Cool  NB, Canada   

 Posted: Nov 13, 2021 07:12PM
Total posts: 499
Last post: Apr 14, 2024
Member since:Jan 25, 2017
Cars in Garage: 0
Photos: 0
WorkBench Posts: 0
You nailed it. 1st try. I struggled with this since March.

 Posted: Nov 13, 2021 02:01PM
Total posts: 8592
Last post: Apr 6, 2024
Member since:Sep 30, 2002
Cars in Garage: 4
Photos: 40
WorkBench Posts: 2
CA
YAY!

Have seen this a little bit in my job (Electronics Engineering TEchnologist) but more often on my old cars, bikes & tractors actually.

Glad you got it resolved.

  ~ 30 minutes in a Mini is more therapeutic than 3 sessions @ the shrink. ~

  Mike  Cool  NB, Canada   

 Posted: Nov 12, 2021 07:15PM
 Edited:  Nov 13, 2021 04:51AM
Total posts: 499
Last post: Apr 14, 2024
Member since:Jan 25, 2017
Cars in Garage: 0
Photos: 0
WorkBench Posts: 0
HooRay, I finally solved the problem. Because all of a sudden the same stalling thing started again. This time I only had 2 wires to deal with. To make a long story short, it turned out to be the crimping of the spade connectors. One of wires was not crimped tight enough. It turns out it was just tight enough to make an electrical connection but not a solid connection. With a new spade,  tinning the wire end again and a new tight crimp, my mini is running fabulous and feels great in acceleration once again.

I guess I'm a candidate for "Lucas, the Prince of Darkness's Apprentice".
Like I said, you are the smart guys, especially the ones insisting that the spade connectors were the culprits. Nick, I did solder the fuse block rivets and terminals which solved the intermittent turn signal glitch.

 Posted: Mar 15, 2021 05:17AM
 Edited:  Mar 15, 2021 05:17AM
Total posts: 499
Last post: Apr 14, 2024
Member since:Jan 25, 2017
Cars in Garage: 0
Photos: 0
WorkBench Posts: 0
Dan, By isolating the one wire, the mini has not stalled. If it does again, I would suspect the relay.

Minibitz, I took all the individual buss fuse cases and put them on an aftermarket fuse block. It is not the main 4 fuse block.

Thank you guys, I do appreciate the feedback. Just a real puzzle to me. The main seems to be running fine again. If it does stall again, I will know that my fix did not work. So far so good. You guys are the smartest out there.

 Posted: Mar 14, 2021 06:11PM
Total posts: 379
Last post: Feb 6, 2024
Member since:Jul 26, 2010
Cars in Garage: 0
Photos: 0
WorkBench Posts: 0
Corrosion inside the fusebox assembly perhaps?

I know on MK4 cars with the four blade fuse box the fuse holders are riveted to the spade that wires attach to. Over time corrosion builds up behind the rivet and causes intermittent power issues. It's a very common problem I see in my workshop. Perhaps the fusebox you have used has a similar construction?

 Posted: Mar 14, 2021 07:56AM
Total posts: 9539
Last post: Apr 13, 2024
Member since:Aug 14, 2002
Cars in Garage: 0
Photos: 0
WorkBench Posts: 0
CA
Have you checked the connections at the fuel pump relay and at the pump itself? Could be coincidence that poking at it at the fuses occurred at the same time as the intermittent connection elsewhere. (As likely as a chafed wire?)

.

"Hang on a minute lads....I've got a great idea."

 Posted: Mar 14, 2021 07:39AM
 Edited:  Mar 14, 2021 01:03PM
Total posts: 499
Last post: Apr 14, 2024
Member since:Jan 25, 2017
Cars in Garage: 0
Photos: 0
WorkBench Posts: 0
I was wondering about that. I did traced the wires backed to the main harness where it they are wrapped. I did not want to start cutting the wrapping off. I will look again.

I just got back from looking at the wires- no chafing. I doubt that the wires would chafe in the harness. Plus the mini is running fine with the wire isolated and the harness still wrapped.

 Posted: Mar 13, 2021 06:52PM
Total posts: 589
Last post: Mar 14, 2024
Member since:May 29, 2001
Cars in Garage: 0
Photos: 0
WorkBench Posts: 0
US
The wires are chafed at another place on the wires other than the connectors causing the wire to ground out. When you moved the wires the chafed portion of the wires no longer hits or rubs against what ever it was hitting or rubbing.

 Posted: Mar 13, 2021 06:27PM
Total posts: 499
Last post: Apr 14, 2024
Member since:Jan 25, 2017
Cars in Garage: 0
Photos: 0
WorkBench Posts: 0
Just to let you guys know. In my post I did change the connectors. When I change them, I made sure they were solidly connected. I tinned the tips of the wires. No difference. Still stalled. When I separated the Brown/grey wires out of the fuse block with a new Buss holder, fuse and lead wires, all I did was to add 2 new male connectors to the lead ends and just pushed  the existing female connectors into the male spade or the other way round. Both the female and the male have the plastic covers. In doing that, it was a plug and play, with no stalling. I appreciate the replies but I have to say t loose connectors were not the problem. As far as heat is concerned, I would think it would be hotter under the air cleaner by a few degrees, as the original fuses were closer to the exhaust manifold and the cleaner trapping the heat.

 Posted: Mar 13, 2021 03:18PM
Total posts: 1059
Last post: Jan 10, 2024
Member since:Feb 25, 1999
Cars in Garage: 0
Photos: 0
WorkBench Posts: 0
If ve9aa is right about the crimp(s), and the crimps are exposed to the engine bay without a cover, maybe the combination of poor crimp(s) and dirt (non-conductive dirt that is) make it an intermittent fault. Either way my electrical mantra covers all, "Connections, connections, connections....."

'72 Morris Mini - 1310cc, K1100 head conversion

 

 

 

 Posted: Mar 13, 2021 01:31PM
Total posts: 8592
Last post: Apr 6, 2024
Member since:Sep 30, 2002
Cars in Garage: 4
Photos: 40
WorkBench Posts: 2
CA
Quote:
Originally Posted by 6464s
Background- A SPI mini used daily. I got rid of the individual fuses holders under the air cleaner and put an 8 gang fuse block using the flat blade fuses. Instead of having them under the cleaner they live on top of the air cleaner. I've been running this set up for years.

Now the Puzzle- Recently the mini would stall every once in a while. To get it started, I would run my fingers across the 7 wires in a row. It would fire right up. I figured out which wires were problematic. Brown and grey wires were the culprits (fuel pump relay). I changed the spade connectors. Fine for a while but still on occasion would stall. I lived with this for a while, maybe a year. Then last week, it stalled 3 times in about an hour, of course it would stall right in the middle of an intersection. When I got it home it was time to fix this problem.



The fix- I tried moving the wires to another position on the fuse block- problem did not go away. I moved the wires again, this time using a different fuse- problem did not go away. I decided to isolate the wires by taking them off the fuse block and went back to using a buss fuse. Problem solved. It's been a week of driving with no issues. 

Can anyone solve this puzzle? Thanks Jim
Bad crimp on one of the wires Jim? Heats up above aircleaner (heat rises, above exhaust manifold, crimp opens ever-so-slightly,(microns) then you don't have as good of a connection anymore.

Just a guess.

  ~ 30 minutes in a Mini is more therapeutic than 3 sessions @ the shrink. ~

  Mike  Cool  NB, Canada   

 Posted: Mar 13, 2021 10:52AM
Total posts: 499
Last post: Apr 14, 2024
Member since:Jan 25, 2017
Cars in Garage: 0
Photos: 0
WorkBench Posts: 0
Background- A SPI mini used daily. I got rid of the individual fuses holders under the air cleaner and put an 8 gang fuse block using the flat blade fuses. Instead of having them under the cleaner they live on top of the air cleaner. I've been running this set up for years.

Now the Puzzle- Recently the mini would stall every once in a while. To get it started, I would run my fingers across the 7 wires in a row. It would fire right up. I figured out which wires were problematic. Brown and grey wires were the culprits (fuel pump relay). I changed the spade connectors. Fine for a while but still on occasion would stall. I lived with this for a while, maybe a year. Then last week, it stalled 3 times in about an hour, of course it would stall right in the middle of an intersection. When I got it home it was time to fix this problem.

The fix- I tried moving the wires to another position on the fuse block- problem did not go away. I moved the wires again, this time using a different fuse- problem did not go away. I decided to isolate the wires by taking them off the fuse block and went back to using a buss fuse. Problem solved. It's been a week of driving with no issues. 

Can anyone solve this puzzle? Thanks Jim